Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 365
Filtrar
2.
J Endovasc Ther ; : 15266028241245341, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597263

RESUMO

OBJECTIVES: Electrosurgery has been long used in endovascular procedures, with only case reports in the aortic field. Our aim is to present a case series with the use of an electrified wire to perform catheter-based electrosurgery by applying external current through an electrocautery pen. METHODS: Single-center retrospective case series of all patients undergoing complex aortic surgery from October 2020 to August 2023, in whom the electrified wire technique was used: (1) Perforation of a dissection flap or left subclavian artery (LSA) in situ endograft fenestration-a 0.014" polytetrafluoroethylene (PTFE) insulated guidewire is detached from the insulation with a scalpel at the end and a cautery pen is here attached with a clamp. A curved tip catheter or sheath is positioned against the aortic flap or the endograft (through a left brachial access in this case) and the wire pushed, crossing the flap by activating the electrocautery pen and (2) slicing a dissection flap ("powered cheese-wire technique")-after same preparation as above, the middle section of the 0.014 guidewire is removed from the PTFE and bent into a V-shape. Once in the aorta, the guidewire crosses from the true lumen (TL) to the false lumen (FL) and a through-and-through access is obtained. Sheaths are positioned against the flap from both sides and moved up or down while the electricity is activated, slicing the flap and communicating both lumens. Technical success and technical-related complications were evaluated. RESULTS: Eleven cases concerning aortic dissections and 1 case of aortic atresia were treated. Four patients presented urgently, whereas the rest were planned procedures. Seven cases underwent perforation of a dissection flap, 2 cases underwent the powered cheese-wire technique, in 2 cases for an LSA in situ fenestration, and in 1 case to cross an aortic atresia at the aortic isthmus. The technique was in all cases successfully applied. No complications related to the technique occurred. CONCLUSIONS: The "electrified wire" technique is a feasible and ready-available tool that can be safely used in complex aortic interventions, especially to perforate aortic tissue like dissection flaps or to perform in situ fenestrated repairs by perforation of the endograft fabric. CLINICAL IMPACT: The electrified wire technique described herein is a straightforward technique that uses readily available tools to perform electrosurgery. We present its use in complex aortic procedures. However, it could be envisioned for any vascular procedure that requires crossing of the vessel or even prosthetic material. As we have described in this series, when used along with an adequate properative planning, it can be a safe tool of great utility, as has already been demonstarted in the field of the interventional cardiology.

3.
JACC Case Rep ; 29(10): 102320, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38601848

RESUMO

Novel dedicated devices allow transcatheter treatment of pure aortic regurgitation (AR). The JenaValve Trilogy Heart Valve System was introduced as the first dedicated and on-label AR transcatheter aortic valve replacement system, implementing a locator-based and calcium-independent anchoring mechanism. Here, we present the first-in-human transcatheter aortic valve replacement for pure AR via a transcaval access in a patient with prohibitive alternative arterial accesses.

4.
J Vasc Surg Cases Innov Tech ; 10(3): 101467, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38591014

RESUMO

Objective: Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic septotomy (TEAS) before stent graft implantation under intravascular ultrasound (IVUS) and fusion guidance. The purpose of this study is to assess the outcomes of TEAS during complex endovascular repair of dissecting aneurysms. Methods: From 2021 to 2023, 17 patients underwent TEAS. The primary end point was technical success, with secondary end points of proximal and distal seals, target vessel instability, aortic and iliac TL and cross-sectional area (CSA) expansion, and aortic-related death. During the procedure, the aortic septum is crossed through a pre-existing entry or via electrocautery-activated 0.018-in. Astato XS20 wire (Asahi-Intecc) under IVUS and fusion guidance. The penetrated wire is then snared in the false lumen and pulled through the ipsilateral femoral access. A 1-cm length of the middle of the Astato wire coating is kinked in a three-sided polygonal configuration, denuded the inner surface of the wire using a no. 15 blade, and positioned at the apex of the septum. Both ends of the Astato wire are insulated with 0.018-in. microcatheters, and the back end of the wire is denuded and connected to cautery. Gentle traction is applied to the wire, and short bursts of electrocautery cutting are applied at 60 to 80 W. Results: The technical success of the septotomy was 100%. No incidence of visceral or lower extremity malperfusion, vascular injury, or distal embolization occurred. Of the 17 patients, 4 underwent thoracic endovascular aneurysm repair, 2 underwent endovascular aortic repair, and 11 underwent fenestrated/branched endovascular aneurysm repair after septotomy. All target vessels were successfully stented. A distal landing zone seal with exclusion of the false lumen was achieved in 16 of the 17 patients (94.1%). One patient required embolization of the false lumen of the celiac artery after septotomy. The TL mean diameter and CSA of the descending thoracic aorta after septotomy was expanded by 7.01 ± 1.9 mm (relative mean diameter expansion, 42.3%; P < .0001) and 2.71 ± 0.4 cm2 (relative mean CSA expansion, 57.3%, P<.0001). For patients who required septotomy through the common iliac arteries, the mean TL was expanded by 8.1 ± 3.7 mm (relative mean diameter expansion, 76%; P < .0001) and 1.76 ± 0.91 cm2 (relative mean CSA expansion, 209%; P < .0001). The 1-year freedom from target vessel instability was 91%. Conclusions: The use of IVUS and fusion-guided TEAS offers a promising technique to facilitate TL expansion and false lumen exclusion in chronic dissecting aortic aneurysms before repair. The durability and long-term outcomes of this technique in a larger cohort remain to be elucidated.

5.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
7.
J Gynecol Obstet Hum Reprod ; 53(5): 102753, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38395411

RESUMO

BACKGROUND: Surgeons use electrosurgery daily, though most of them are unfamiliar with its basic safety principles. METHOD: We have designed a hands-on simulation session to teach OBGYN trainees principles of electrosurgery with practical implications for safety in the operating room. 15 participants completed post-session surveys. EXPERIENCE: Our experience of serially refining teaching materials and electrosurgery demonstrations resulted in a comprehensive guide to electrosurgery in OBGYN. CONCLUSION: This report will allow surgeon educators to implement simulation training in their institutions.

8.
Diagnostics (Basel) ; 14(3)2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38337854

RESUMO

Breast conserving resection with free margins is the gold standard treatment for early breast cancer recommended by guidelines worldwide. Therefore, reliable discrimination between normal and malignant tissue at the resection margins is essential. In this study, normal and abnormal tissue samples from breast cancer patients were characterized ex vivo by optical emission spectroscopy (OES) based on ionized atoms and molecules generated during electrosurgical treatment. The aim of the study was to determine spectroscopic features which are typical for healthy and neoplastic breast tissue allowing for future real-time tissue differentiation and margin assessment during breast cancer surgery. A total of 972 spectra generated by electrosurgical sparking on normal and abnormal tissue were used for support vector classifier (SVC) training. Specific spectroscopic features were selected for the classification of tissues in the included breast cancer patients. The average classification accuracy for all patients was 96.9%. Normal and abnormal breast tissue could be differentiated with a mean sensitivity of 94.8%, a specificity of 99.0%, a positive predictive value (PPV) of 99.1% and a negative predictive value (NPV) of 96.1%. For 66.6% patients all classifications reached 100%. Based on this convincing data, a future clinical application of OES-based tissue differentiation in breast cancer surgery seems to be feasible.

11.
J Obstet Gynaecol Res ; 50(4): 639-646, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38185922

RESUMO

AIM: To seek the high-risk factors of human papillomavirus (HPV) persistence and residual lesion or recurrence after loop electrosurgical excision procedure (LEEP) focus on the predictive value of intraoperative human papilloma virus (IOP-HPV) testing. METHODS: Intraoperative endocervical sample was obtained with a cytobrush from the remained cervix of 292 patients immediately after LEEP. HPV Genotyping was performed using a polymerase chain reaction technique. All patients followed by HPV genotyping and cytology every 3-6 months. The IOP-HPV testing results and possible risk factors such as age, cytology grade, menopause status, margin involvement, preoperative HPV status, and cervical lesion grade were assessed in predicting persistence of HPV and residual lesion or recurrence after surgery. RESULTS: There were 61 (20.9%) patients presented persistent HPV infection. Multivariate analyses showed that IOP-HPV positive, post-menopause and preoperative HPV multiplex infection was strongly associated with HPV persistence after LEEP, IOP-HPV positive and post-menopause was also associated with residua or recurrent disease after LEEP. CONCLUSIONS: IOP-HPV positive, post-menopause, and preoperative HPV multiplex infection are independent predictors of HPV persistence in patients with cervical squamous intraepithelial lesion treated by LEEP. IOP-HPV test is a new approach that may potentially allow for early identification of patients at high risk of HPV persistence and residua or recurrent disease after LEEP, thereby possibly facilitate an attenuated follow-up schedule for negative patients those at low risk of persistent HPV infection.


Assuntos
Infecções por Papillomavirus , Lesões Intraepiteliais Escamosas , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/patologia , Infecções por Papillomavirus/complicações , Papillomavirus Humano , Eletrocirurgia/métodos , Displasia do Colo do Útero/patologia , Lesões Intraepiteliais Escamosas/cirurgia , Lesões Intraepiteliais Escamosas/complicações , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos
12.
J R Soc Interface ; 21(210): 20230420, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38228182

RESUMO

In this paper, we propose a method to model radiofrequency electrosurgery to capture the phenomena at higher temperatures and present the methods for parameter estimation. Experimental data taken from our surgical trials performed on in vivo porcine liver show that a non-Fourier Maxwell-Cattaneo-type model can be suitable for this application when used in combination with an Arrhenius-type model that approximates the energy dissipation in physical and chemical reactions. The resulting model structure has the advantage of higher accuracy than existing ones, while reducing the computation time required.


Assuntos
Eletrocirurgia , Temperatura Alta , Animais , Suínos , Eletrocirurgia/métodos , Fígado/cirurgia , Condutividade Térmica , Ondas de Rádio
13.
Minim Invasive Ther Allied Technol ; 33(1): 1-12, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38164811

RESUMO

INTRODUCTION: Hemostasis is an important step in all surgical procedures. Mechanical methods of hemostasis have been gradually abandoned in favor of electrosurgery. The aim of this systematic review was to evaluate the effectiveness of electrosurgical instruments utilized in minimally invasive gynecological procedures. MATERIAL AND METHODS: We performed a systematic review, including randomized controlled trials, prospective and retrospective studies, comparing the outcomes of different energy devices (EDs) used in laparoscopic gynecologic surgeries. We extracted data about blood loss (BL), mean operative time, post-operative pain, hospital stay and complications associated with each electrosurgical device. RESULTS: We included 30 studies reporting comparative outcomes concerning conventional (bipolar and monopolar) and innovative EDs (Harmonic scalpel, LigaSure, Plasma kinetic gyrus, Thunderbeat, EnSeal, Marseal, Caiman and ALAN). New EDs were found to be more efficient in complex surgeries due to less intraoperative BL and shorter operative time. No significant decrease in hospital stay, post-operative pain or complications was found with the use of new energy instruments. CONCLUSIONS: Although new electrosurgical devices seem an appealing and safer option, there is still insufficient evidence for one vessel-sealing technology to be considered superior to another. Therefore, monopolar and conventional bipolar (CB) are still widely used in laparoscopic gynecology.


Assuntos
Laparoscopia , Humanos , Feminino , Estudos Retrospectivos , Estudos Prospectivos , Laparoscopia/métodos , Eletrocirurgia/métodos , Dor Pós-Operatória/epidemiologia
14.
J Cardiovasc Electrophysiol ; 35(1): 16-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890041

RESUMO

INTRODUCTION: Mechanical force to achieve transseptal puncture (TSP) using a standard needle may lead to overshooting and injury, and can potentially be avoided using a radiofrequency (RF)-powered needle or wire. Applying electrocautery to needles and guidewires as an alternative to purpose-built RF systems has been associated with safety risks, such as tissue coring and thermal damage. The commercially available AcQCross needle-dilator system (Medtronic) features a sharp open-ended needle for mechanical puncture, as well as a built-in connector to enable energy delivery for RF puncture. This investigation compares the safety and efficacy of the AcQCross needle to the dedicated VersaCross RF wire system and generator (Baylis Medical/Boston Scientific). METHODS: In an ex vivo porcine model, VersaCross wire punctures were performed using 1 s, constant mode (approx. 10 W) with maximum two attempts. AcQCross punctures were performed by applying energy for 2 s using a standard electrosurgical generator at 10 W (max. five attempts), 20 W (max. two attempts), and 30 W (max. two attempts). Efficacy was assessed in terms of puncture success and a number of energy applications required for TSP. Safety was assessed quantitatively as force required for TSP, energy required to puncture, and incidence of tissue coring, as well as by qualitative assessment of puncture sites. Additional qualitative observation of tissue cores and debris were obtained from TSP performed in live swine. RESULTS: RF TSP was 100% successful using the VersaCross wire with 1.0 ± 0.0 attempts. When power was used with the AcQCross needle, it failed to puncture at low (10 and 20 W) power settings; TSP was achieved with 30 W of energy with 91% success using 1.53 ± 0.51 attempts (p < .05 vs. VC) with greater variability (F1,33 = 9223.5, p < .0001). Compared to RF puncture using the VersaCross system, mechanical puncture, alone, using the AcQcross needle required six times more force (8 mm additional forward device displacement) to perforate the septum. Qualitative assessment of puncture sites revealed larger defects and more tissue charring with the AcQCross needle at 30 W compared to punctures with VersaCross wire. Tissue coring with the open-ended AcQCross needle was observed in vivo and measured to occur in 57% of punctures using the ex vivo model; no coring was observed with the closed-tip VersaCross wire. CONCLUSIONS: The AcQCross needle frequently required higher energy of 30 W to achieve RF TSP and was associated with tissue coring and charring, which have been, previously, reported when electrifying a standard open-ended mechanical needle or guidewire. These findings may limit safety and effectiveness compared to the VersaCross system.


Assuntos
Ablação por Cateter , Suínos , Animais , Desenho de Equipamento , Eletrocoagulação , Agulhas , Punções , Modelos Animais , Resultado do Tratamento
15.
Otolaryngol Head Neck Surg ; 170(2): 505-514, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37811571

RESUMO

OBJECTIVE: Comprehensively assess the prevalence of monopolar electrosurgery-related device complications among cochlear implant (CI) recipients. STUDY DESIGN: Multifaceted retrospective review and survey. SETTING: Tertiary medical center. METHODS: Multifaceted approach including: (i) review of the current literature; (ii) historical review of institutional data from an academic, tertiary CI center; (iii) review of industry data provided by 3 Food and Drug Administration-approved CI manufacturers; and (iv) survey of high-volume CI centers. RESULTS: Literature review identified 9 human studies, detailing 84 devices with 199 episodes of device-cautery exposure. From studies reporting on patients records, no implant showed evidence of damage after exposure. One cadaveric study using dental cautery reported 1 episode of device damage. Review of institutional records did not identify any CI damage in 84 instances of exposure. Data from the 3 major implant manufacturers showed a single report of damage that could be reasonably linked to monopolar electrosurgery, out of a possible 689,426 CIs. Last, a survey of 8 high-volume CI centers did not identify any adverse events associated with monopolar cautery. CONCLUSION: These data estimate the risk of adverse device-related events or tissue injury to be extraordinarily low. Short of operating in immediate proximity to the CI (ie, the ipsilateral temporoparietal scalp), these data indicate that monopolar electrosurgery can be used in the body and the head-and-neck of CI recipients with nominal risk. These findings may guide decision-making in cases that are optimally or preferably performed with monopolar electrocautery and can be used to counsel CI patients following inadvertent exposures.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Eletrocirurgia/efeitos adversos , Implantes Cocleares/efeitos adversos , Eletrocoagulação , Implante Coclear/efeitos adversos , Cauterização
16.
J Vet Cardiol ; 51: 64-71, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38091683

RESUMO

Transseptal puncture is necessary to access the left atrium and mitral valve from a transvenous approach but is poorly described in veterinary medicine. The procedure is generally regarded as difficult and dangerous, particularly given the size of most small animal patients. Precise imaging is paramount to the procedure to ensure that puncture occurs within the desired location and to monitor for potential complications. Transesophageal echocardiography, including biplanar two-dimensional and particularly three-dimensional modalities, has great potential to improve the success and safety of transseptal puncture due to superior visualization of the fossa ovalis and other intracardiac structures. Here, we describe the use of transesophageal echocardiography to guide transseptal puncture based on our experience in 159 dogs, with an emphasis on three-dimensional echocardiography. We also detail how to perform transseptal puncture from a jugular approach, which we consider preferable in most patients. Complications from transseptal puncture are discussed, along with ways to limit those complications.

17.
JTCVS Tech ; 22: 189-196, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152237

RESUMO

Objective: Electrosurgical laceration and stabilization of mitral clips (ELASTA-CLIP) is a bail-out technique to recreate a single-orifice mitral valve after transcatheter edge-to-edge repair (TEER) with subsequent transcatheter mitral valve replacement (TMVR). This technique is a novel option for patients with significant residual mitral regurgitation after TEER with high risk for conventional surgery. The original ELASTA CLIP procedure features a transseptal approach, whereas the TMVR with the Tendyne bioprosthesis has a transapical access. Hereby we tested the hypothesis that a modified transapical ELASTA CLIP technique can be safely applied transapically allowing a straightforward one-stop shop access strategy. Methods: We developed the procedural steps in a porcine passive-beating heart model and applied the modified technique with subsequent TMVR in 2 consecutive patients with severe mitral regurgitation after previous TEER. Patients were followed up to 30 days. Results: The modified transapical ELASTA CLIP procedure was successful in both patients. The mean total procedure time was 118 minutes, and the mean fluoroscopy duration 22 minutes. At 30 days' follow-up, both patients were alive without bleeding complications, reintervention, or prosthetic valve dysfunction. Conclusions: The modified transapical ELASTA CLIP procedure is technically feasible and safe at 30 days. Procedure times are lower compared with previous reports of the original transseptal approach.

18.
Wiad Lek ; 76(10): 2277-2282, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37948726

RESUMO

OBJECTIVE: The aim: To increase the efficiency of surgical treatment of patients with chronic lung abscesses by developing mini-invasive methods of surgical treatment using electrosurgical technologies. PATIENTS AND METHODS: Materials and methods: Conducted study of the results of surgical treatment of 78 patients with chronic lung abscesses operated from 2011 to 2021. Patients were divided into two groups: the main group (37 patients who were treated using developed technologies) and a comparison group (41 patients, treated using traditional tactics). RESULTS: Results: Transthoracic and endobronchial sanitation of the purulent cavity in the lung at the first stage of treatment contributed to the rapid elimination of inflammation and significantly accelerated the regeneration of lung tissue. Clinical effectiveness in the main group was expressed in reducing the phenomena of intoxication, decrease in Leukocyte intoxication index (LII) (early as on day 5 after surgery), on the 10th day, a significant reduction in patients bacterial excretion was noted (in the main group by 18.9%, in the comparison group - by 14.6%), the average time of reducing the abscess cavity by 1/4 of the volume 6 days less, the healing time of the cavity of the AL which is on average 13 and 16 days, respectively, less. CONCLUSION: Conclusions: The developed methods of surgical interventions made it possible to significantly positively influence the level of endogenous intoxication indicators, avoid resection surgical interventions, reduce the number of postoperative complications, avoid damage to neighboring organs, reduce the time of patients with achieving a stable positive effect.


Assuntos
Abscesso Pulmonar , Humanos , Abscesso Pulmonar/cirurgia , Eletrocirurgia , Cicatrização , Resultado do Tratamento , Inflamação/cirurgia
19.
J Electr Bioimpedance ; 14(1): 32-46, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38025910

RESUMO

Electrosurgical generators (ESG) are widely used in medical procedures to cut and coagulate tissue. Accurate control of the output power is crucial for surgical success, but can be challenging to achieve. In this paper, a novel expert knowledge-based peak current mode controller (EK-PCMC) is proposed to regulate the output power of an ESG. The EK-PCMC leverages expert knowledge to adapt to changes in tissue impedance during surgical procedures. We compared the performance of the EK-PCMC with the classical peak current mode controller (PCMC) and fuzzy PID controller. The results demonstrate that the EK-PCMC significantly outperformed the PCMC, reducing the integral square error (ISE) and integral absolute error (IAE) by a factor of 3.88 and 4.86, respectively. In addition, the EK-PCMC outperformed the fuzzy PID controller in terms of transient response and steady-state performance. Our study highlights the effectiveness of the proposed EK-PCMC in improving the regulation of the output power of an ESG and improving surgical outcomes.

20.
Clin Cosmet Investig Dermatol ; 16: 2773-2780, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37818198

RESUMO

Introduction: Anogenital warts (AGW) is one of the sexually transmitted infections (STIs) caused by human papillomavirus (HPV). Treatment modalities of AGW yield low clearance and recurrence rate, so that chemical cautery with trichloroacetic acid (TCA) and electrosurgery are widely used to remove the lesions without any severe side effects. Objective: To investigate the efficacy of chemical cautery with TCA and electrosurgery in AGW based on clinical trials or case series. Methods: The systematic review was reported according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) but not registered to the International Prospective Register of Systematic Review (PROSPERO). To acquire proper and accurate information from relevant literature, two databases PubMed and the Cochrane Library were searched from January 2013 to March 2023. Results: Thirteen studies were included in this systematic review, comprising seven articles on chemical cautery and six electrosurgery articles. The highest cure rate of chemical cautery with TCA was 94.1% while electrosurgery was 100%. A relatively low recurrence rate during 1 year follow-up was observed in electrosurgery with 14.6%, whereas the chemical cautery was 27.6%. Conclusion: Electrosurgery for AGW treatment had higher cure rate with lower recurrence rate compared to chemical cautery with TCA. Numerous adverse effects of electrosurgery were reported include bleeding and scar formation as high risk of HPV infection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...